How we verify every number

The short answer

Every figure comes from a public data file we downloaded and dated, run through one published formula. We never type a price or an efficiency by hand. Weather is NOAA, prices are EIA, equipment is ENERGY STAR (EPA), geography is Census. Where a source was unavailable we say so below instead of filling the gap.

Inputs

What goes into an estimate
InputSourceNotes
Hourly temperatureNOAA ISD-Lite via the AWS open-data bucket122 airport stations, 2015–2024. Lowest coverage: Minneapolis, MN at 87.5% of hours.
Electricity priceEIA electricity dataResidential, trailing twelve months to August 2026, per state.
Gas, oil, propaneEIA SEDS2024 state residential prices per million BTU of fuel. Annual average, so seasonal swings are not modelled.
Heat pump capacity and efficiencyENERGY STAR Certified Mini-Split Heat Pumps14,941 cold-climate rows from 218 brands: capacity at 47°F, 17°F and 5°F, COP at 5°F, HSPF2.
ZIP to climateCensus 2020 ZCTAZIP centroid to the nearest of our 122 stations by great-circle distance, and to the state with the largest county overlap.

Formulas

  1. Design temperature is the 99% hourly percentile of 2015–2024 temperatures at the station (the temperature that 99% of hours are warmer than). It is not the ASHRAE published value, which is licensed; ours comes from a ten-year window and may be milder.
  2. Load line. Heat loss is zero at 65°F and equals your design load at the design temperature, straight line in between. UA = load ÷ (65°F − design temp).
  3. Capacity. Linear between the 5°F and 47°F ENERGY STAR points, flat above 47°F, never rising below 5°F. The 17°F number is displayed but not used, because it is reported under a different test condition.
  4. COP. Linear from the 5°F COP to the seasonal COP (HSPF2 ÷ 3.412) at 47°F. This is conservative because HSPF2 already averages cold hours.
  5. Backup. Whenever load exceeds capacity, the shortfall is met by electric resistance at 1.0 COP.
  6. Cost. Σ over 5°F bins of (hours × energy) × price. Fuels divide by the furnace or boiler efficiency (90% unless you change it in the calculator).
  7. Reference unit. The median across all 14,941 cold-climate systems: 5°F capacity 88% of 47°F (10th to 90th percentile: 71% to 103%), HSPF2 10, COP at 5°F 2. Unit sized so rated capacity at the design temperature equals the load.

What we do not model

What we could not verify

Changes to this method are dated here. Last reviewed 2026-10-26. Raw and cleaned files are on the data page.